<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>medical battery - Custom Power</title>
	<atom:link href="https://custompower.co.uk/tag/medical-battery/feed/" rel="self" type="application/rss+xml" />
	<link>https://custompower.co.uk/tag/medical-battery/</link>
	<description>Custom Power is a specialist UK based battery pack manufacturer, providing custom designed and custom built battery packs for use in harsh environments.</description>
	<lastBuildDate>Tue, 19 Mar 2024 16:22:24 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://custompower.co.uk/wp-content/uploads/2024/03/Custom-Power-Insignia-Favicon-32-x-32-px.png</url>
	<title>medical battery - Custom Power</title>
	<link>https://custompower.co.uk/tag/medical-battery/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Custom Designed Batteries for the Medical Sector</title>
		<link>https://custompower.co.uk/custom-designed-medical-batteries/</link>
					<comments>https://custompower.co.uk/custom-designed-medical-batteries/#respond</comments>
		
		<dc:creator><![CDATA[Natalie Ryan]]></dc:creator>
		<pubDate>Tue, 17 Oct 2023 09:20:22 +0000</pubDate>
				<category><![CDATA[Battery Pack Insights]]></category>
		<category><![CDATA[power]]></category>
		<category><![CDATA[Custom battery pack]]></category>
		<category><![CDATA[battery packs]]></category>
		<category><![CDATA[battery]]></category>
		<category><![CDATA[lithium battery]]></category>
		<category><![CDATA[batteries]]></category>
		<category><![CDATA[lithium battery packs]]></category>
		<category><![CDATA[Energy]]></category>
		<category><![CDATA[single cell]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[li-ion]]></category>
		<category><![CDATA[custom batteries]]></category>
		<category><![CDATA[Lithium battery transportation]]></category>
		<category><![CDATA[battery engineering]]></category>
		<category><![CDATA[BMS]]></category>
		<category><![CDATA[Transportation]]></category>
		<category><![CDATA[Battery management system]]></category>
		<category><![CDATA[medical battery]]></category>
		<category><![CDATA[Rechargeable]]></category>
		<category><![CDATA[batteries for medical]]></category>
		<category><![CDATA[Custom lithium battery packs]]></category>
		<guid isPermaLink="false">https://custompower.co.uk/?p=8820</guid>

					<description><![CDATA[<p>Any equipment used in the front line of surgical or medical applications must meet the stringent requirements and industry standards of this demanding sector...</p>
<p>The post <a href="https://custompower.co.uk/custom-designed-medical-batteries/">Custom Designed Batteries for the Medical Sector</a> appeared first on <a href="https://custompower.co.uk">Custom Power</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid vc_custom_1552048436834 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-8820-1961698580]" href="https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-1024x576.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="1600" height="900" src="https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries.jpg" class="vc_single_image-img attachment-full" alt="A medical professional holding a battery powered medical device" title="Custom-designed-medical-batteries" srcset="https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries.jpg 1600w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-300x169.jpg 300w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-1024x576.jpg 1024w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-768x432.jpg 768w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-1536x864.jpg 1536w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-260x146.jpg 260w, https://custompower.co.uk/wp-content/uploads/2023/10/Custom-designed-medical-batteries-150x84.jpg 150w" sizes="(max-width: 1600px) 100vw, 1600px" /></a>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697534555399" >
		<div class="wpb_wrapper">
			<p>Any equipment used in the front line of surgical or medical applications must meet the stringent requirements and industry standards of this demanding sector.</p>
<p>Steatite has decades of experience in designing, prototyping and manufacturing batteries for use in healthcare settings, and our capabilities in this area are extensive.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538105928" >
		<div class="wpb_wrapper">
			<h2>What are the common requirements for medical batteries?<strong><strong><br />
</strong></strong></h2>
<p>The paramount requirement in supplying battery packs for medical applications is reliability. Batteries must run continuously, often for lengthy procedures, without experiencing overheating or variation in discharge performance.</p>
<p>Battery packs must meet rigorous safety standards to prevent any risks of fire, explosions, or leakage of hazardous substances. A BMS (Battery Management System) should be incorporated to provide built-in protection mechanisms, such as protection against overcharge, over-discharge and short-circuiting.</p>
<p>Being able to easily monitor the battery’s state of charge is also essential. Some devices even require a certain threshold capacity before they are operable at all, to ensure that they don’t require changing or charging at a critical point of surgery.</p>
<p>Almost all batteries for use in the medical sector will need to comply with <a href="https://webstore.iec.ch/publication/70017" target="_blank" rel="noopener">IEC 62133</a> or its regional equivalent. This is an international standard for the safety of rechargeable batteries, and is a cornerstone for obtaining approval for devices from the UK Medicines and Healthcare products Regulatory Agency (MHRA), US Food and Drug Administration (FDA) and other global regulatory bodies.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538117859" >
		<div class="wpb_wrapper">
			<h2>Our proven expertise</h2>
<p>We have several customers in the medical sector who have specified a range of parameters for their power requirements, so we have various tried-and-tested battery designs for this industry.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538128466" >
		<div class="wpb_wrapper">
			<h2><strong>Examples of existing Steatite battery systems</strong></h2>
<h2>Patient monitoring systems</h2>
<p>We currently supply a battery consisting of 2S3P 18650 cells for a ruggedised ambulatory patient monitoring system, capable of recording and transmitting patient data from first responders directly to A&amp;E departments and receiving hospitals.</p>
<p>The cell selection enables the monitor to perform across the widest operational environments while maintaining and communicating critical patient data. The lithium-ion 7.4V 10.2Ah battery is built and tested to the highest tolerances using free issue plastics maintaining the IP66 rating for the device and its UN certification. It also includes a TI fuel gauge and state of charge LED indicators.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538137615" >
		<div class="wpb_wrapper">
			<h2>Hand-held surgical power</h2>
<p>For another customer, our team has developed power packs for battery-operated tools for bone surgery to deliver consistent, reliable power within a highly-regulated medical environment. The range includes both Nickel-Metal Hydride (NiMh), Lithium Ion and Lithium Ferro Phosphate (LiFePO4) batteries. NiMh cells offer good power delivery, tolerate a wide operating temperature, and can be less complex than lithium alternatives. Where runtime and comfort are important, our Lithium based options improve overall energy density including battery capacity-to-weight ratio by around 25% and an increase in delivered power of up to 20%.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538146134" >
		<div class="wpb_wrapper">
			<h2>Battery-powered ventilators</h2>
<p>Another medical customer approached us about providing batteries for its range of portable ventilators. The result was a new rechargeable battery solution that is the sole source of energy for the equipment, including one internal and one external battery, all thoroughly tested and compliant to medical standards.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538155804" >
		<div class="wpb_wrapper">
			<h2>Powered air-purifying respirators (PAPRs)</h2>
<p>For these devices, we have designed batteries with bespoke mechanical enclosures fit for respiratory protection in harsh and critical environments, which may be helmet integrated or body worn. We’ve engineered solutions using both NiMH cells, which are recommended for hazardous areas, and Li-ion cells where space, weight, run time and whole life costs are important.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="800" height="450" src="https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities.jpg" class="vc_single_image-img attachment-full" alt="A medical professional wearing a Powered air-purifying respirator" title="Steatite Medical Battery Capabilities" srcset="https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities.jpg 800w, https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities-300x169.jpg 300w, https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities-768x432.jpg 768w, https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities-260x146.jpg 260w, https://custompower.co.uk/wp-content/uploads/2023/10/Steatite-medical-battery-capabilities-150x84.jpg 150w" sizes="(max-width: 800px) 100vw, 800px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538167240" >
		<div class="wpb_wrapper">
			<h2>Portable microwave devices</h2>
<p>Our battery design skills have also been put to good use for a compact and portable device in the fight against cancer. Our team was involved right from the beginning of a new project and helped guide the manufacturer through the cell selection process, battery design, prototype development, testing and final production. We also designed the electronics for the custom-built charging station.</p>
<p>One stipulation for this project was that the customer requested all our electronics to establish a <a href="https://en.wikipedia.org/wiki/Handshake_(computing)" target="_blank" rel="noopener">handshaking</a> protocol in order to operate, meaning that batteries couldn’t be replaced at a later date with alternative models which may not have been tested to the correct medical standards.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538175911" >
		<div class="wpb_wrapper">
			<h2>Mobile ultrasound</h2>
<p>In the veterinary  sector, where adaptability to diverse weather conditions and limited space are the norm, handheld devices are essential tools.</p>
<p>Partnering with <a href="https://www.imv-imaging.com/en/" target="_blank" rel="noopener">IMV</a>, the leaders in veterinary imaging, we supply cutting-edge battery technology that powers their reliable handheld porcine ultrasound devices. This collaboration yields several thousand units annually, demonstrating both companies’ commitment to powering innovation. Together with IMV, we&#8217;ve engineered a robust and enclosed power solution, specially designed for monitoring lively piglets in challenging environments. This collaboration showcases our dedication to delivering advanced, reliable, and versatile solutions for the veterinary industry.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538184281" >
		<div class="wpb_wrapper">
			<h2>Medical carts and UPSs</h2>
<p>Another customer in the medical sector has benefitted from our lead acid battery provision for medical carts. These provide an uninterruptible power supply (UPS) to provide automated backup power in the event of battery or mains failure. Therefore, it goes without saying that reliability is absolutely critical.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1552052665161 vc_row-has-fill"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1697538491937" >
		<div class="wpb_wrapper">
			<h2>Why choose Steatite?</h2>
<p>Our large portfolio of customers in the medical sector prove that we are trusted to deliver reliable and efficient battery solutions to this industry. Many of our designs are already certified to IEC 62133 or UL 62133 and these designs can be quickly customised by our expert team to fit the space, power and performance requirements of a huge range of medical devices and scenarios.</p>
<p>In addition to our proficiency in power, we have further capabilities across the business and can combine solutions beyond just batteries.</p>
<p>For example, we offer a wide selection of <a href="https://steatite-embedded.co.uk/medical/" target="_blank" rel="noopener">computers and panel PCs</a> specifically for medical applications. Many of these are certified to EN60601 and incorporate IP rated enclosures to allow for thorough cleaning, plus the transmission of viruses and bacteria is prevented by anti-microbial housing.</p>
<p>Our imaging business unit, Active Silicon, is a leading provider of <a href="https://www.activesilicon.com/capabilities/medical-computer-imaging-solutions/" target="_blank" rel="noopener">imaging products</a> for surgical microscopy, ophthalmology, patient positioning systems and other medical devices. Embedded vision systems support computer vision assisted surgery, frame grabbers enhance image acquisition for digital slide scanners and autofocus-zoom cameras capture and transmit HD video for real-time viewing and training purposes.</p>
<p>If you’re involved with designing and manufacturing medical devices, <a href="https://custompower.co.uk/contact-us/" target="_blank" rel="noopener">contact our team</a> to discuss your requirements and see what proven products we can offer or modify to meet your exact needs.</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://custompower.co.uk/custom-designed-medical-batteries/">Custom Designed Batteries for the Medical Sector</a> appeared first on <a href="https://custompower.co.uk">Custom Power</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://custompower.co.uk/custom-designed-medical-batteries/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
